The Cressall AC100 load bank is designed for on-site testing of three-phase AC generators and power supplies at 400/230V at continuous powers adjustable up to 100kW.
Capacity
400V 3 phase, 50/60Hz: 100kW in 1.25kW steps
230V 1 phase 50/60Hz: 33kW in 400W steps
Other AC voltages
Lower AC test voltages can be applied; the maximum power is reduced accordingly.
For example: 220V 3 phase, 50/60Hz: 28kW in 350W steps
110V 1 phase, 50/60Hz: 7kW in 85W steps
Resistor Elements
Metal sheathed wire elements manufactured from high-grade nickel/chrome resistance wire in magnesium oxide insulated stainless steel tubes and 600V primary insulation.
Every model is complete with all meters, controls and power leads with quick-release in-line connectors.
Controls
Integral control panel with hinged weatherproof lid with:
1 – 48mm DIN voltmeter 0-500V linear with selector switch
1 – 48mm DIN ammeter 0-150A linear with selector switch
1 – 48mm DIN frequency meter 45-65Hz
7 – ‘on/off’ pushbuttons (1.25, 2.5, 5, 10, 20, 20, 40kW)
7 – indicator lamps, one per section
1 – ‘on/off’ pushbutton for fan start/stop
1 – indicator lamp ‘fans running’
1 – input socket for external 220/240V AC supply, with selector switch
1 – emergency stop button
Cooling
Fan cooled with a single 450mm fan powered from the test load itself or an external supply. The fan is mounted in the base of the load bank and blows vertically through mesh bird screens top and bottom.
Capacity
30kW at 400V, 3 phase, in sections of 1, 2 x 2, 5 and 2 x 10kW
15kW at 230V, 1 phase, in steps of 333W
Test voltages
380/415V, 3 phase 50/60Hz
220/240V, 1 phase 50/60Hz
Controls
Integral control panel with:
1 – 48mm DIN voltmeter 0-500V
3 – 48mm DIN ammeter 0-80A linear
1 – 48mm DIN frequency meter 45-65Hz
2 – single pole MCB’s for short circuit protection
1 – meter fuse
Resistor Elements
Cressall expanded mesh and mica card elements made from with high-grade nickel-chrome stainless steel with 750V insulation.
For testing single and three phase generators 0-30kW
Cooling
Fan cooled with four 150mm fans powered from the test load itself. The fans are mounted under the load bank and blow vertically and out through mesh screens on each side.
Input cables and connectors: Two 63A colour coded input connectors to IEC-60309-2 are fitted as standard.
Case: All aluminium, finished in red powder coat, with instructions and warning labels, handles and castors.
Dimensions: 560 x 400 x 840mm high
Weight: 30kg complete
AC6 Dual Voltage for testing portable generators up to 6kW, 110V and 230V AC
Capacity
0-6kW in 333W switched steps of 333W. 666W, 3 x 1kW and 1 x 2kW, switched in any combination.
At 110V this dual voltage version is limited to 3.5kW by the IEC-60309-2 32A plug connector.
Test voltages
Two switch-selected voltage ranges:
220-240V, 1 phase 50/60Hz
110-120V, 1 phase 50/60Hz
Controls
Integral control panel with removable weatherproof lid with:
1 – 48mm DIN voltmeter 0-300V linear
1 – 48mm DIN ammeter 0-100A linear
1 – 48mm DIN frequency meter 45-65Hz
1 – 3 position rotary switch 110V – OFF – 230V
2 – single pole MCB’s for protection
1 – meter fuse
Resistor Elements
Mica card elements wound with high-grade nickel-chrome stainless steel resistance tape with 600V primary insulation.
Cooling
Fan cooled with a single 170mm fan powered from the test load itself. The fan is mounted on one side of the load bank and blows horizontally through mesh screens on each side.
Input cables and connectors
Two 1.5m flexible input cables complete with colour coded input connectors to IEC-60309-2 are fitted as standard.
Case
All aluminium, finished in red powder coat, with instructions and warning labels. The load bank is fitted with a detachable cover with carrying handle and built-in cable stowage box.
Dimensions: 495 x 220 x 550mm high
Weight: 12kg complete
AC6 DUAL VOLTAGE
AC6 SINGLE VOLTAGE
AC6 Single Voltage for testing portable generators 6kW, 230V AC
Capacity
0-6kW in 333W switched steps of 333W. 666W, 3 x 1kW and 1 x 2kW, switched in any combination.
Test voltages
220 – 240V, 1 phase 50/60Hz
Controls
Integral control panel with removable weatherproof lid with:
1 – 48mm DIN voltmeter 0-300V linear
1 – 48mm DIN ammeter 0-100A linear
1 – 48mm DIN frequency meter 45-65Hz
1 – switching ON – OFF
1 – two pole MCB’s for protection
6 – on/off toggle switches
1 – meter fuse
Resistor Elements
Mica card elements wound with high-grade nickel-chrome stainless steel resistance tape with 600V primary insulation.
Cooling
Fan cooled with a single 170mm fan powered from the test load itself. The fan is mounted on one side of the load bank and blows horizontally through mesh screens on each side.
Input cables and connectors
One 1.5m flexible input cable complete with colour coded input connector to IEC-60309-2 is fitted as standard.
Case
All aluminium, finished in red powder coat, with instructions and warning labels. The load bank is fitted with a hinged cover with carrying handle and built-in cable stowage box.
Dimensions: 495 x 220 x 415mm high
Weight: 10kg complete
The Dual 30 load bank is designed for site testing of DC batteries and AC generators and power supplies of 120 to 240V, AC or DC, at continuous powers adjustable up to 30kW and is complete with all indications, controls and power leads.
Capacity
Controls
Resistor Elements
Expanded mesh and mica card elements wound with high-grade nickel-chrome stainless steel resistance tape with 750V primary insulation.
Cooling
Fan cooled by one 300mm axial fan powered from an external 220/240V supply. The fans are mounted under the load bank and blow vertically through mesh screens on each side.
Ammeter shunt
Rating: 100A = 100mV
Input cables and connectors
Two 2.5m 70mm2 flexible input cables complete with M12 lugs and quick-release connectors.
Case
All aluminium, finished in grey powder coat, with instructions and warning labels. The load bank is fitted with a carrying handle and four omni-directional braked castors.
Dimensions:
500 x 600 x 800mm high: Weight 50kg complete